VW Passat repair


+ 1. Ekspluatatsiiya of the car
+ 2. Maintenance
+ 3. Engines
+ 4. Cooling system
+ 5. Power supply system
+ 6. Ignition system
+ 7. Coupling
+ 8. Transmission
+ 9. Drive of forward wheels
+ 10. Suspension brackets
+ 11. Steering
+ 12. Brake system
+ 13. Wheels and tires
- 14. Systems of heating, ventilation and conditioning
   14.1. Technical characteristics
   14.2. General information
   14.3. Central air with a circulating coolant
   14.4. Precautionary measures at central air service
   + 14.5. Search of malfunctions
   14.6. Conditioner filling by a coolant
   14.7. Search and elimination of malfunctions in heating and conditioning systems
   14.8. Airdistributing box
   14.9. Fan
   14.10. Cover of airinflow and vacuum system
   14.11. Vozdukho-priyemnik
   + 14.12. Heater fan
   + 14.13. Management cables
   + 14.14. Central air units
   + 14.15. Basic provisions on conditioner service
+ 15. Electric equipment
+ 16. Body
+ 17. Electric circuits


429b39f6





Repair B3-B4/Passat B3-B4 Volkswagen Passat>> Systems of heating, ventilation and conditioning>> Conditioner filling by a coolant

Fig. 14.7. The observation port (it is specified by an arrow) gives the chance to estimate level of the filled coolant


Fig. 14.5. An arrangement of units and central air knots in a motor compartment and a vacuum drive of a zaslonka рециркуляции / inflow: 1–union of a vacuum hose (drive of a cover of airinflow); 2–relay of the electromagnetic coupling of coupling of the compressor of the conditioner and fan relay обдува heater radiator; 3–vacuum tank; 4–dvukhkhodovy distributor of a drive of a cover of airinflow; 5–control vacuum gate; 6–condenser; 7–compressor of the conditioner and electromagnetic coupling of coupling of the compressor; 8–a broad tank with a moisture separator and a safety valve; 9–service cap of the valve of a high pressure; 10-sensor of pressure of turning on of the conditioner; 11-sensor of temperature of zabortny air; 12-service cap of the valve of low pressure; 13-broad valve; 14-drainage valve of the evaporator


For effective work of central air the necessary quantity of a coolant and its corresponding filling is required. Low pressure in system and insufficient quantity of a coolant lead to fall of overall performance of the evaporator, and at very small quantity — to conditioner self-shutdown because of operation of the sensor of pressure. Even at an insignificant leak the filled quantity of a coolant will constantly go down that will demand new filling of system. In central air the observation port intended for a rough estimate of level of the filled coolant is provided. The observation port (fig. 14.7) is located on the right side of a motor compartment and built in the highway of a high pressure between the service valve of a high pressure and a broad tank 8 (see fig. 14.5 ) with a moisture separator.
For check of level of a coolant start up the engine and turn on the conditioner. At the working compressor in an observation port it should not be observed vials. Presence of vials at least and on a short period testifies to insufficient filling of a coolant. Emergence of signs of foaming on inside of viewing glass can indicate almost total absence of a coolant. For a complete recovery of operability of central air the highway of system should be pumped out, checked on tightness and refuel the prepared personnel with use of the appropriate equipment.